Vokèra XF/XV 'Click Fit' Flue Kit – Horizontal & Vertical
Genuine Vokèra 'Click fit' flue kits. A flue must be purchased with every boiler — choose the horizontal (XF) kit for a standard through-wall installation, or the vertical (XV) kit for flat or pitched roof terminations.
- Genuine Vokèra flue components
- 60/100mm concentric
- 'Click fit' design for fast, secure assembly
- Approved for C13 and C33 flue applications
- Fixings included
Product Details
| Brand | Vokèra (distributed by Kartell UK) |
|---|---|
| Type | Concentric flue kit, 60/100mm ('X-type' click fit) |
| Flue applications | C13 (horizontal) and C33 (vertical) |
| XF Horizontal | 796mm centre to end |
| XV Vertical | 1000mm plus vertical connector |
| Outlet rotation | Flue outlet elbow rotates through 360° on its vertical axis |
Which one do I need?
- Horizontal XF (20122759) — the standard choice where the flue passes out through an external wall. The concentric pipe is cut to length on site to suit your wall thickness. Both horizontal terminals have an eccentric configuration so condensate drains back to the appliance, and the terminal must be installed level.
- Vertical XV (20122763) — for terminations through a flat or pitched roof. Important: the vertical flue terminal is 1.0 metre in length and cannot be cut, so it may be necessary to adjust the mounting height of the boiler or add an extension to suit. A roof flashing is required and is ordered separately.
Compatible Boilers
These kits are listed in the manufacturer's installation manuals for the following Vokèra ranges:
- Pinnacle combi and Pinnacle system
- Synergy combi and Synergy system
- Vibe MAX combi and Vibe MAX system
- Easi-Heat i combi and Easi-Heat i system
Extensions, Bends & Accessories
Longer or more complex flue routes can be built up using the Vokèra 60/100mm accessory range:
| Code | Description | Length / Size |
|---|---|---|
| 20132060 | 0.5-Metre Extension | 500mm |
| 20132061 | 1.0-Metre Extension | 1000mm |
| 20132062 | 2.0-Metre Extension | 2000mm |
| 20131979 | Telescopic Extension | 372–519mm |
| 20132059 | 90-Degree Bend | — |
| 20132058 | 45-Degree Bend (pair) | — |
| 20122761 | XT Telescopic 'Click fit' Flue Kit | 400–575mm C/E |
| 20121903 | Vertical Connector 'Click Fit' VC | 131mm |
| 20142842 | PMK Plume Kit | 1370mm |
| 20142841 | 45° Plume Diverter | — |
| 20132050 | Pitched Roof Flashing | 500 x 500mm |
| 20135582 | Flat Roof Flashing | 340mm dia. |
| 20135587 | Wall Brackets | 208mm C/E |
Contact us with your flue route and we will confirm exactly what your installer needs.
Maximum Flue Lengths
Maximum permitted flue lengths, and the length reduction applied for each additional bend, vary between boiler models and outputs — they are not the same across the Vokèra range. Always check the installation manual for your specific boiler, or contact us to confirm before ordering extensions and bends.
Any horizontal run that incorporates extensions must have a fall back towards the appliance so condensate drains correctly, and the entire flue system must be fully supported and sealed at the wall.
Range Codes
| Code | Model | Length |
|---|---|---|
| 20122759 | Vokèra XF Horizontal 'Click fit' Flue Kit | 796mm C/E |
| 20122763 | Vokèra XV Vertical 'Click fit' Flue Kit | 1000mm + VC |
Please note: gas appliances and flues must be installed by a Gas Safe registered engineer, who should confirm the flue route and terminal position before installation. Contact us if you are unsure which flue and accessories your installation requires.